Education, Science, Technology, Innovation and Life
Open Access
Sign In

Research and analysis of orthodontic force

Download as PDF

DOI: 10.23977/medsc.2024.050222 | Downloads: 1 | Views: 156

Author(s)

Fan Fan 1, Quanwang Fan 2

Affiliation(s)

1 Taiyuan Hospital of Peking University First Hospital, Taiyuan, Shanxi, 030025, China
2 Shanxi Workers Jinci Sanatorium, Taiyuan, Shanxi, 030025, China

Corresponding Author

Quanwang Fan

ABSTRACT

Although contemporary orthodontics has established a relatively complete system, the planning of treatment options and the preparation of orthodontic appliances still heavily rely on the personal experience of orthodontists. However, orthodontists cannot predict the orthodontic force generated by the appliances, leading to frequent follow-up visits and adjustments, which result in a "trial and error" treatment approach. This not only prolongs treatment time and increases treatment costs but also brings additional side effects. Currently, orthodontic treatment in clinical treatment period is long, and side effects are large. Therefore, shortening the clinical treatment time is essential. This article analyzes the biomechanics of orthodontics and discusses the reasonable range of orthodontic forces, aiming to provide reference for shortening the clinical treatment time of orthodontics.

KEYWORDS

Orthodontic force; orthodontics; biomechanics

CITE THIS PAPER

Fan Fan, Quanwang Fan, Research and analysis of orthodontic force. MEDS Clinical Medicine (2024) Vol. 5: 138-143. DOI: http://dx.doi.org/10.23977/medsc.2024.050222.

REFERENCES

[1] LeRoy Johnson A, Appleton Jr J L, Rittershofer L S. Tissue changes involved in tooth movement[J]. International Journal of Orthodontia, Oral Surgery and Radiography, 1926, 12(10): 889-898.
[2] Keilig L, Piesche K, Jager A, et al. Applications of surface matching algorithms for determination of orthodontic tooth movements[J]. Computer Methods in Biomechanics and Biomedical Engineering, 2003, 6(5): 353-359.
[3] Yoshida N, Koga Y, Saimoto A, et al. Development of a magnetic sensing device for tooth displacement under orthodontic forces[J]. IEEE Transactions on Biomedical Engineering, 2001, 48(3): 354-360.
[4] Cevidanes L H, Styner M A, Proffit W R. Image analysis and superimposition of 3-dimensional cone-beam computed tomography models[J]. American Journal of Orthodontics and Dentofacial Orthopedics, 2006, 129(5): 611-618.
[5] Yadav S, Chen J, and Jiang F. Comparison of the force systems of three appliances on palatally impacted canine[J]. American Journal of Orthodontics and Dentofacial Orthopedics, 2011, 139(2): 206-213.
[6] Field C, Ichim I, Swain M V, et al. Mechanical responses to orthodontic loading: a 3-dimensional finite element multi-tooth model[J]. American Journal of Orthodontics and Dentofacial Orthopedics, 2009, 135(2): 174-181.
[7] Kroczek C, Kula K, Fu T, et al. Comparison of the orthodontic load systems created with elastomeric power chain to close extraction spaces on different rectangular archwires[J]. American Journal of Orthodontics and Dentofacial Orthopedics, 2012, 141(3): 262-268.
[8] Xia Z, Jiang F, Chen J. Estimation of Periodontal Ligament's Equivalent Mechanical Parameters for Finite Element Modeling [J]. American Journal of Orthodontics and Dentofacial Orthopedics, 2013, 143(4): 486-491.
[9] Xia Z, Chen J. Biomechanical validation of a Tooth-PDL-Bone Complex for in-vitro orthodontic load measurement [J]. The Angle Orthodontist, 2013, 84(3): 410-417.
[10] Qian Y, Fan Y, Liu Z, et al. Numerical simulation of tooth movement in a therapy period[J]. Clinical Biomechanics, 2008, 23: S48-S52.

Downloads: 5016
Visits: 227757

Sponsors, Associates, and Links


All published work is licensed under a Creative Commons Attribution 4.0 International License.

Copyright © 2016 - 2031 Clausius Scientific Press Inc. All Rights Reserved.