Education, Science, Technology, Innovation and Life
Open Access
Sign In

Study on seismic response of a new double story isolated structure

Download as PDF

DOI: 10.23977/jceup.2023.051101 | Downloads: 10 | Views: 266

Author(s)

Hang Shan 1, Dewen Liu 1, Zhiang Li 1, Fusong Peng 1, Tiange Zhao 1

Affiliation(s)

1 College of Civil Engineering, Southwest Forestry University, Kunming, 650000, China

Corresponding Author

Dewen Liu

ABSTRACT

The traditional double story isolated structure is a type of isolated structure developed from base isolated structure and inter-story isolated structure. The new double story isolated structure is a new type of isolated structure developed from traditional double story isolated structure. In order to study the seismic response of the new double story isolated structure, the model of the structure was established. At the same time, models of basic fixed, base isolated, inter-story isolated and traditional double story isolated structures were established. The nonlinear dynamic time history response of the new double story isolated structure under rare earthquakes was analyzed. The study shows that compared to basic fixed, the new double story isolated structure has superior performance in all aspects. Compared with base isolated and inter-story isolated, the new double story isolated structure can significantly reduce the inter-story shear force, top acceleration, and inter-frame displacement of the structure. The horizontal displacement of the new double story isolated structure is concentrated on the two isolated layers of the structure, dissipating most of the input seismic energy. Compared with the traditional double story isolated structure, the new one reduces the displacement of the inter-isolation layer in the middle of the frame, ensuring the integrity of the core tube and avoiding collapse and damage of the structure.

KEYWORDS

New double story isolated structure; traditional double story isolated structure; high-rise building; base isolated structure; inter-story isolated structure

CITE THIS PAPER

Hang Shan, Dewen Liu, Zhiang Li, Fusong Peng, Tiange Zhao, Study on seismic response of a new double story isolated structure. Journal of Civil Engineering and Urban Planning (2023) Vol. 5: 1-11. DOI: http://dx.doi.org/10.23977/jceup.2023.051101.

REFERENCES

[1] Ye, D.F., Liu, Y.F., Qin, X., Tan, P., & Zhou, F.L. (2021). Stochastic response analysis of foundation seismic isolated structures based on probability density evolution. Journal of Earthquake Engineering.
[2] Arisa Nakai, Daiki Sato, Tomokazu Murakami, & Kazuhiko Kasai. (2018). Evaluation of stiffness of seismic isolated layer and superstructure based on seismic motion observation records of high-rise seismically isolated buildings. Technical Report of the Architectural Institute of Japan, 24(57), 571-576.
[3] Gupta, P. K., Ghosh, G., & Pandey, D. K. (2021). Parametric study of effects of vertical ground motions on base isolated structures. Journal of Earthquake Engineering, 25(3), 434-454.
[4] Zhou, F. L., Zhang, Y., & Tan, P. (2009). A theoretical study of layer spacing seismic systems. Journal of Civil Engineering, (8), 1-8. 
[5] Ishizawa, H., & Kobiyama, M. (2014). Estimation of Maximum Response of Intermediate-Layer Seismic Isolated Buildings by Complex Perfect Quadratic Coupling Method Considering Peak Factor for Each Mode. In Proceedings of the 63rd Theoretical and Applied Mechanics Conference (p. 188). Science Council of Japan "Joint IUTAM Subcommittee of the Committee on Mechanical Engineering and the Committee on Civil Engineering and Architecture". 
[6] Park, H. S., Kim, H. S., & Kang, J. W. (2019). Seismic Response Control of Mid-Story Isolated System for Planar Irregular Structures. Journal of Korean Association for Spatial Structures, 19(2), 109-116.
[7] Ou, Jin-Ping, Wu, Pei-Song, & Guan, Xin-Chun. (2021). Large displacement friction pendulum subgrade and multilayer seismically isolated ductile structures. Journal of Disaster Prevention and Mitigation Engineering. 
[8] Zhang Y, Tan P, & Zhou F-L. (2010). Parameter design and seismic performance study of a new system of segmental seismic isolated. Journal of Civil Engineering, (S1), 270-275. 
[9] Jianping Gao, Dan Luo, & Yueyue Pan. (2011). Optimization of passive control parameters for segmental seismic isolators of high-rise buildings with transition floors. Journal of East China Jiaotong University, 28(4), 23-29. 
[10] Pan, Yueyue. (2011). Energy-based optimization of passive control parameters for segmental seismic isolated system of high-rise buildings (Master's thesis, East China Jiaotong University). 
[11] Qiao, L. V. (2013). Analysis of nonlinear dynamic characteristics of segmental isolated structures (Doctoral dissertation, Qinhuangdao: Yanshan University). 
[12] Wu, Qiaoyun, He, Wancheng, & Zhu, Hongping. (2020). Seismic Isolated Effect of Hybrid Passive Control System under Different Frequency Domain Ground Shaking. Journal of Lanzhou University of Technology, 46(2), 121. 
[13] Wu Qiaoyun, Liu Ziliang, Yan Huichao, He Wancheng, & Zhu Hongping. (2022). Experimental study on the influence of the change in the position of the intervening seismic layer on the control effect of hybrid passive control system. Journal of Vibration Engineering, 35(1), 1-12. 
[14] Hu, Baoqing, Mu, Lin, & Zhao, Yonggang. (2013). Dynamic time analysis of segmental seismic isolated structures of high-rise buildings under two-way horizontal earthquakes. Gansu Journal of Science, 25(3), 88-92. 
[15] Wang, X. Q. (2006). A New SMA-Laminated Rubber Bearing and its Segmental Vibration Isolated in High-Rise Buildings. 
[16] Architectural Institute of Japan. Translated by Liu Man-kwong. Design of seismically isolated structures [M]. Beijing: Earthquake Press, 2006 
[17] Ministry of Housing and Urban-Rural Development of the People's Republic of China, General Administration of Quality Supervision, Inspection and Quarantine. Code for seismic design of buildings: GB50011-2010 [S]. Beijing: China Construction Industry Press, 2010.

All published work is licensed under a Creative Commons Attribution 4.0 International License.